CERI L-columns and G-columns supplied in India by Akira Analytical Solutions Pvt. Ltd.
CERI GC columns

CERI G-column GC Phases

CERI G-columns are wide-bore open tubular GC column phase options for routine and specialized gas chromatography methods.

G-columnLiquid phase compositionEquivalent phasePolarityMaximum temperatureMain applicationAvailable size family
CERI G-100Methyl SiliconeSE-30 / OV-1 / OV-101 / SP-2100Non-polar280°C; high film thickness 5 µm: 250°CGeneral GC analysis and solvent analysis20 m and 40 m options depending on film thickness; 10 m available at selected 1 µm format; inner diameter 1.2 mm
CERI G-2055% Phenyl methyl siliconeSE-52 / SE-54Slightly polar310°C; high film thickness 5 µm: 250°CGeneral analysis and solvent analysis20 m and 40 m options across 0.1, 0.5, 1, 2 and 5 µm; 10 m available at selected 1 µm format; inner diameter 1.2 mm
CERI G-23030% Phenyl methyl siliconeOV-61 / DC-550Low polarity300°CAnalysis of slightly polar compounds20 m and 40 m options across 0.5, 1 and 2 µm; inner diameter 1.2 mm
CERI G-25050% Phenyl methyl siliconeOV-17Medium polarity300°CSteroids, pharmaceuticals, pesticides and other medium-polar compounds20 m and 40 m options at 0.5 and 1 µm; inner diameter 1.2 mm
CERI G-300Polyethylene glycolPEG-20MStrongly polar220°CPolar compound analysis20 m and 40 m options across 0.5, 1 and 2 µm; inner diameter 1.2 mm
CERI G-45050% Trifluoropropyl methyl siliconeDC-QF-1Medium polarity230°CCis-trans isomer analysis and fluorinated-phase selectivity20 m and 40 m options at 1 µm; inner diameter 1.2 mm
CERI G-950Porous polymerPorapak Q typeSpecial porous polymer phase200°CLow-boiling compounds and gas analysis20 m and 40 m options at 25 µm; inner diameter 1.2 mm

Frequently Asked Questions

Helpful answers for column selection, specifications and technical support.

What are CERI G-Columns used for?

CERI G-Columns are GC columns designed for gas chromatography methods requiring defined phase selectivity, reliable separation behavior and method-support documentation.

Which G-Column phases are included?

The G-Column family includes CERI G-100, G-205, G-230, G-250, G-300, G-450 and G-950, each with its own dedicated technical page.

How should I select a CERI G-Column phase?

Selection depends on the validated method, target compounds, phase polarity, column dimensions, film thickness and required catalog number.

Can G-Columns support replacement enquiries?

Yes. For replacement enquiries, share the existing GC column phase, dimensions, film thickness and application so the closest CERI G-Column option can be reviewed.

Where are G-Column catalog numbers shown?

Catalog numbers and available specification details are listed on the searchable specifications page and on the relevant G-Column product pages.